Notes:

(1) The ‘Dust Loading’ and Particle Size guidelines are average. 
They will tend to vary from installation to installation. 
The ranges are as follows:

Dust Loading: Light: 0.5 to 5 g/m3
Medium: 5-7 g/m3 
Moderate: 7-11 g/m3 
Heavy: Over 11 g/m3
 
Particle Size: Extremely Fine: 50% - ½ to 2 microns
Fine: 50% : 2 to 7 microns 
Medium: 50% 7-15 microns 
Coarse: 50% to 15 microns

(2) Notes:
A:
B:
C:
D:
E:
F:
G:
P:
X:
Pulseflo fabric filter frequently used. 
Wet Scrubber frequently used. 
Includes conveying, elevating, mixing, packaging.
Multiclone collectors used to recover maximum quantities of fines.
Electrostatic precipitator often required as the final collector
Fractionating Multiclone collectors used. 
Thermoflex filter frequently used.
Used as a pre-cleaner with a secondary collector
Used as a final collector. 

 